This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions 

The official URL for this profile is:
http://hl7.org/fhir/StructureDefinition/qicore-device
Profile of Device for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
This profile was published on Wed, Mar 11, 2015 00:00+1100 as a draft by Health Level Seven International (Clinical Quality Information - QICore).

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Device.
This structure is derived from Device.
| Name | Flags | Card. | Type | Description & Constraints![]() |
|---|---|---|---|---|
![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() | ∑ | 0..1 | Meta | Metadata about the resource |
![]() ![]() | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
![]() ![]() | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() | 0..* | Extension | Additional Content defined by implementations | |
![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() | 0..* | Identifier | Instance identifier | |
![]() ![]() | 0..1 | Identifier | Unique Device Identifier (UDI) Barcode string | |
![]() ![]() | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
![]() ![]() | S | 1..1 | CodeableConcept | What kind of device this is Binding: Device Types (example) |
![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() | 0..1 | dateTime | Date when the device was made | |
![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() | 0..1 | string | Model id assigned by the manufacturer | |
![]() ![]() | 0..1 | string | Version number (i.e. software) | |
![]() ![]() | S | 0..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
![]() ![]() | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
![]() ![]() | 0..1 | uri | Network address to contact device | |
![]() ![]() | 0..* | Annotation | Device notes and comments | |
Documentation for this format | ||||
todo
This structure is derived from Device.
Differential View
This structure is derived from Device.
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints![]() |
|---|---|---|---|---|
![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() | ∑ | 0..1 | Meta | Metadata about the resource |
![]() ![]() | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
![]() ![]() | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() | 0..* | Extension | Additional Content defined by implementations | |
![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() | 0..* | Identifier | Instance identifier | |
![]() ![]() | 0..1 | Identifier | Unique Device Identifier (UDI) Barcode string | |
![]() ![]() | ?! S∑ | 0..1 | code | available | not-available | entered-in-error Binding: DeviceStatus (required) |
![]() ![]() | S | 1..1 | CodeableConcept | What kind of device this is Binding: Device Types (example) |
![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() | 0..1 | dateTime | Date when the device was made | |
![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() | 0..1 | string | Model id assigned by the manufacturer | |
![]() ![]() | 0..1 | string | Version number (i.e. software) | |
![]() ![]() | S | 0..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
![]() ![]() | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
![]() ![]() | 0..1 | uri | Network address to contact device | |
![]() ![]() | 0..* | Annotation | Device notes and comments | |
Documentation for this format | ||||
XML Template
JSON Template
todo
Other representations of profile: Schematron

| Path | Name | Conformance | ValueSet |
| Device.language | ?ext | required | http://tools.ietf.org/html/bcp47 ![]() |
| Device.status | DeviceStatus | required | DeviceStatus |
| Device.type | Device Types | example | Device Types |

| Id | Path | Details | Requirements |